Kyung Eun Lee1, Soon-sung Kwon2, Eun Bo Shim3
09:00 - 09:15 | Wed 24 Jul | M4 - Level 3 | WeA11.3
We developed a vessel length-based fractional flow reserve (FFR) simulation method in patient-specific models and compared the results with clinical results. In this method, vessel lengths are used to identify simulation parameters. Then, we evaluate its clinical diagnostic performance in multi-center study.